{"id":13966,"date":"2022-03-11T19:54:08","date_gmt":"2022-03-11T19:54:08","guid":{"rendered":"https:\/\/wolles-elektronikkiste.de\/logic-analyzer"},"modified":"2022-11-04T14:12:31","modified_gmt":"2022-11-04T14:12:31","slug":"logic-analyzer","status":"publish","type":"post","link":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer","title":{"rendered":"Logic Analyzer"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"uber-den-beitrag\">About this post<\/h2>\n\n<p>In this article I will introduce the 8-channel 24 MHz Logic Analyzer and the Logic 2 software. After hearing a lot about it, I recently took a closer look &#8211; and I really like it. Especially for troubleshooting and analyzing data transmissions, I find the device extremely useful.<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-1024x410.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"410\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-1024x410.jpg\" alt=\"\" class=\"wp-image-13629\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-1024x410.jpg 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-300x120.jpg 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-768x308.jpg 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-1536x615.jpg 1536w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-2048x820.jpg 2048w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_all_views-1320x529.jpg 1320w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>The 24 MHz, 8-channel Logic Analyzer<\/figcaption><\/figure>\n<p>This is what you can expect:<\/p>\r\n<ul>\r\n<li><a href=\"#basics\">Logic Analyzer &#8211; Basics and Properties<\/a><\/li>\r\n<li><a href=\"#logic2\">Logic 2 &#8211; Overview<\/a><\/li>\r\n<li><a href=\"#loop_time_trig\">Looping, Timer and Trigger measurements<\/a>\r\n<ul>\r\n<li><a href=\"#looping\">looping<\/a><\/li>\r\n<li><a href=\"#timer\">timer<\/a><\/li>\r\n<li><a href=\"#trigger\">trigger<\/a><\/li>\r\n<\/ul>\r\n<\/li>\r\n<li><a href=\"#analyzers\">analyzer<\/a>\r\n<ul>\r\n<li><a href=\"#Async_Serial\">async serial <\/a><\/li>\r\n<li><a href=\"#i2c\">I2C<\/a><\/li>\r\n<\/ul>\r\n<\/li>\r\n<li><a href=\"#analyzer_export\">export analyzer data<\/a><\/li>\r\n<li><a href=\"#raw_export\">export raw data <\/a><\/li>\r\n<li><a href=\"#other\">Other applications: 433 MHz and IR signals<\/a><a id=\"basics\"><\/a><\/li>\r\n<\/ul>\r\n\n<h2 class=\"wp-block-heading\" id=\"logic-analyzer-grundlagen-eigenschaften\">Logic Analyzer &#8211; Basics \/ Properties<\/h2>\n\n<p>What does a Logic Analyzer do? In short, a logic analyser checks with a certain frequency whether a connected contact (e.g. a pin or a line) is at a HIGH or LOW level. You can think of it like an oscilloscope that only detects the logical states HIGH and LOW. The data is streamed via USB and analyzed by software. However, there are also PC-independent units that contain a display and control unit.&nbsp;<\/p>\r\n<p>The measurement frequency of the Logic Analyzer must be several times the frequency of the signals to be measured. For this article, I use one of the common, inexpensive logic analyzers that are available from as little as \u20ac10 on Amazon or other online shops. With its measuring frequency of 24 MHz, it is sufficient for most applications in the field of microcontrollers.<\/p>\r\n<p>As for the voltage of the logic levels, I have found different information. The limit up to which LOW signals are reliably recognized as LOW seems to be somewhere between 0.6 and 1.0 volts. For the lower limit of the HIGH range, the specifications were between 1.2 and 1.8 volts. I cannot say whether the devices are actually different or just the information provided by the suppliers. They are therefore in any case suitable for the common 5 and 3.3 volt based microcontrollers.<\/p>\r\n\n<p>For devices with higher measuring frequencies, you have to spend considerably more money. At <a href=\"https:\/\/www.saleae.com\/\" target=\"_blank\" rel=\"noopener\">Saleae<\/a> you can get logic analysers that scan at 100 or 500 MHz, but they cost a few hundred to over a thousand euros.<\/p>\r\n<p>The software I use is the free Logic 2 from Saleae. You can download the program <a href=\"https:\/\/www.saleae.com\/downloads\/\" target=\"_blank\" rel=\"noopener\">here<\/a>. The installation is so simple and unproblematic that I won&#8217;t go into it in detail. After installation, connect the Logic Analyzer to the PC, and it will be recognized immediately. At least that was the case with me.<a id=\"logic2\"><\/a><\/p>\r\n\n<p><strong>An attentive reader has pointed out that the licence conditions do not allow Logic 2 to be used with devices from other manufacturers, although it works perfectly!<\/strong> The notice is quite well hidden. I would like to at least mention this. So you would either have to buy a Logic Analyser from Saleae or get an alternative software to avoid violating it.<\/p>\r\n\n<h2 class=\"wp-block-heading\" id=\"logic2\">Logic 2 &#8211; first overview<\/h2>\n\n<p>After you have installed Logic 2, connect the Logic Analyzer to the PC and launch the programme. Here is an overview:<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_Screen-1024x621.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"621\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_Screen-1024x621.png\" alt=\"\" class=\"wp-image-13586\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_Screen-1024x621.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_Screen-300x182.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_Screen-768x466.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_Screen-1320x800.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_Screen.png 1537w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Logic 2 Screen<\/figcaption><\/figure>\n<ol>\r\n<li>Logic 2 window: Logic Analyzer connected or disconnected<\/li>\r\n<li>Main menu<\/li>\r\n<li>Timeline, scalable with +\/- or mouse wheel<\/li>\r\n<li>Channels 0 &#8211; 7<\/li>\r\n<li>Start \/ Stop Button<\/li>\r\n<li>Side menu<\/li>\r\n<li>Device Settings: Logic Analyzer Settings<\/li>\r\n<li>Analyzer: Activation of analysis programs<\/li>\r\n<li>Timing Markers, Measurements &amp; Notes: Evaluation of measurements<\/li>\r\n<li>Extensions: Installable add-ons<\/li>\r\n<li>Communication: click here to access the forum and support<\/li>\r\n<li>Alternative to the main menu<\/li>\r\n<li>Sessions: very convenient to switch between different sessions with different settings<\/li>\r\n<\/ol>\r\n\n<p>You may have noticed that the channels in Logic 2 are numbered from 0 to 7. On the other hand, they are labeled 1 to 8 on the Logic Analyzer. But it&#8217;s just a shift by 1 channel. Channel 1 of the Logic Analyzer is channel 0 in Logic 2, etc.<a id=\"loop_time_trig\"><\/a><\/p>\r\n\n<h2 class=\"wp-block-heading\" id=\"looping-timer-und-trigger-messungen-mit-dem-logic-analyzer\">Looping, Timer and Trigger measurements with the Logic Analyzer<\/h2>\n\n<p>There are three methods to control the timing of the measurements:<\/p>\r\n<ul>\r\n<li><strong>Looping<\/strong>: the measurement is started manually and runs endlessly until it is stopped manually. The measured values are stored in a buffer. When the buffer is full, the oldest values are deleted in favor of new values.<\/li>\r\n<li><strong>Timer<\/strong>: again, you start the measurement manually, but set the duration.<\/li>\r\n<li><strong>Trigger<\/strong>: in this method &#8211; similar to interrupts &#8211; you set an event by which the measurement is started. This could be, for example, a LOW-HIGH change (rising edge). You can freely select the measurement duration.<a id=\"looping\"><\/a><\/li>\r\n<\/ul>\r\n\n<h3 class=\"wp-block-heading\" id=\"looping-messung\">Looping measurements<\/h3>\n\n<p>As a first example, let&#8217;s look at a constant PWM (pulse width modulation) signal generated with an analogWrite() statement. This signal is used to set an LED to a certain brightness. I chose an Arduino Nano as the MCU board. Here is the short sketch:<\/p>\r\n\n<pre class=\"EnlighterJSRAW\" data-enlighter-language=\"generic\" data-enlighter-group=\"analogWrite.ino\" data-enlighter-title=\"analogWrite.ino\">const int analogWritePin = 6;\r\n\r\nvoid setup() {\r\n  pinMode(analogWritePin, OUTPUT);\r\n  analogWrite(analogWritePin, 51);\r\n}\r\n\r\nvoid loop() {}<\/pre>\r\n<p>&nbsp;<\/p>\r\n\n<p>And now to the circuit. Basically, you need a common GND. There are two GND pins on the logic analyzer, which I symbolize here by the socket. We record the PWM signal with pin 1 of the Logic Analyzer.<\/p>\r\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring-1024x326.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring-1024x326.png\" alt=\"PWM measurement with the Logic Analyzer\" class=\"wp-image-13636\" width=\"840\" height=\"267\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring-1024x326.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring-300x95.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring-768x244.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring-1536x489.png 1536w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring-1320x420.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/analogWrite__wiring.png 1590w\" sizes=\"auto, (max-width: 840px) 100vw, 840px\" \/><\/a><figcaption>PWM measurement with the Logic Analyzer<\/figcaption><\/figure>\n<div class=\"wp-block-image\"><figure class=\"alignright size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/loop_setting.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/loop_setting.png\" alt=\"\" class=\"wp-image-13633\" width=\"303\" height=\"428\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/loop_setting.png 404w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/loop_setting-212x300.png 212w\" sizes=\"auto, (max-width: 303px) 100vw, 303px\" \/><\/a><figcaption>Looping Settings<\/figcaption><\/figure><\/div>\n\n<p>Since the signal is permanently present, we can use the looping method. To do this, go to the Device Settings in the side menu and select &#8220;Looping&#8221;. I set 2 MS\/s (= 2 million samples per second) as the measuring frequency. Since the PWM frequency is about 1 kHz, I could have chosen a significantly lower value.<\/p>\r\n<p>With &#8220;Trim data after stopping&#8221; you can reduce the collected data to a certain period of time.<\/p>\r\n<p>The &#8220;glitch filter&#8221; eliminates noise signals. You recognize glitches as signals with a strikingly short duration. If this occurs, then you can activate the filter for the channel in question. You can set a time limit. All signals with a shorter duration are filtered out.&nbsp;&nbsp; <\/p>\r\n<p>The &#8220;Memory buffer size&#8221; determines how much RAM may be used as buffer memory. If the buffer is full, the oldest data is deleted from the buffer.<\/p>\r\n<p>Now is the time: Click on the Start button and then &#8211; whenever you want &#8211; on Stop. Then move the mouse to the result of channel 0 and set the desired scaling with the mouse wheel. If you hold down the left mouse button, you can shift the curve.<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_loop_pwm-1024x396.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"396\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_loop_pwm-1024x396.png\" alt=\"analogWrite \/ PWM analysis with the Logic Analyzer\" class=\"wp-image-13590\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_loop_pwm-1024x396.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_loop_pwm-300x116.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_loop_pwm-768x297.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_loop_pwm-1320x511.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_loop_pwm.png 1537w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>analogWrite \/ PWM Analysis<\/figcaption><\/figure>\n<p>When you move the mouse over the result curve of channel 0, the signal distances, the PWM frequency and the duty cycle are automatically displayed. As expected, the latter is 20 percent.<\/p>\r\n\n<h4 class=\"wp-block-heading\" id=\"messdaten-loschen\">Deleting measured data<\/h4>\n\n<p>If you want to delete data, then right-click at a reference point, go to &#8220;Delete&#8221; and select your option.<a id=\"timer\"><\/a><\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/DeleteData-1.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/DeleteData-1.png\" alt=\"Deleting measured data of the Logic Analyzer\" class=\"wp-image-13597\" width=\"493\" height=\"325\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/DeleteData-1.png 657w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/DeleteData-1-300x198.png 300w\" sizes=\"auto, (max-width: 493px) 100vw, 493px\" \/><\/a><figcaption>Deleting measured data of the Logic Analyzer<\/figcaption><\/figure><\/div>\n\n<h3 class=\"wp-block-heading\" id=\"timer-messung\">Timer measurements<\/h3>\n\n<p>The timer method is useful, for example, if you want to determine the number of events in a certain period of time.<\/p>\r\n<p>You set the length of a timer measurement with &#8220;Stop recording after&#8221;. For the result shown below, I have activated the option &#8220;Trim data after recording&#8221; and set it to 50 milliseconds. I didn&#8217;t change the circuit and the sketch.<a id=\"trigger\"><\/a><\/p>\r\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm-1024x378.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm-1024x378.png\" alt=\"Timer measurement with the Logic Analyzer\" class=\"wp-image-13602\" width=\"840\" height=\"310\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm-1024x378.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm-300x111.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm-768x284.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm-1536x567.png 1536w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm-1320x487.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_timer_pwm.png 1920w\" sizes=\"auto, (max-width: 840px) 100vw, 840px\" \/><\/a><figcaption>Timer measurement with the Logic Analyzer<\/figcaption><\/figure>\n<h3 class=\"wp-block-heading\" id=\"trigger-messung\">Trigger measurements<\/h3>\n\n<p>The trigger method is suitable for individual events and especially if you do not know exactly when they occur. With &#8220;Pattern and Channel&#8221; you define the trigger and set the channel. The trigger can be a rising or falling edge, a HIGH pulse or a LOW pulse. You also determine the duration of the measurement.<\/p>\r\n\n<h4 class=\"wp-block-heading\" id=\"trigger-beispiel-1-taster\">Trigger Example 1: Push-Button<\/h4>\n\n<p>As a first example, I connected a push-button to the Logic Analyzer. In normal state it delivers a LOW to channel 0, when pressed it delivers a HIGH:<\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/push_button_wiring.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/push_button_wiring.png\" alt=\"\" class=\"wp-image-13638\" width=\"500\" height=\"167\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/push_button_wiring.png 999w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/push_button_wiring-300x100.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/push_button_wiring-768x257.png 768w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><figcaption>Push-button circuit<\/figcaption><\/figure><\/div>\n\n<p>I have set a rising edge as the trigger. The measuring time after the trigger signal occurs is 5 seconds. I set the data acquisition to start 500 milliseconds before the trigger signal (&#8220;Trim pre trigger data&#8221;). During the 5 seconds, I pressed the button a few times:<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button-1024x390.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"390\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button-1024x390.png\" alt=\"\" class=\"wp-image-13599\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button-1024x390.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button-300x114.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button-768x292.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button-1536x585.png 1536w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button-1320x503.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_push_button.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Button<\/figcaption><\/figure>\n<p>Admittedly, the example is rather pointless &#8211; but it shows the principle.<\/p>\r\n\n<h4 class=\"wp-block-heading\" id=\"trigger-beispiel-2-hc-sr04\">Trigger Example 2: HC-SR04<\/h4>\n\n<p>The next example makes a little more sense. Here I am examining what happens during a distance measurement with the <a href=\"https:\/\/wolles-elektronikkiste.de\/en\/hc-sr04-and-jsn-sr04t-2-0-distance-sensors\" target=\"_blank\" rel=\"noopener\">HC-SR04<\/a>. This is the circuit:<\/p>\r\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04-1024x469.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04-1024x469.png\" alt=\"Logic Analyzer, connected to the HC-SR04\" class=\"wp-image-13640\" width=\"840\" height=\"384\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04-1024x469.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04-300x138.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04-768x352.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04-1536x704.png 1536w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04-1320x605.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/HC_SR04.png 1597w\" sizes=\"auto, (max-width: 840px) 100vw, 840px\" \/><\/a><figcaption>Logic Analyzer, connected to the HC-SR04<\/figcaption><\/figure>\n<p>The trigger line is monitored with channel 0, the echo line with channel 1.<\/p>\r\n<p>This is the sketch:<\/p>\r\n\n<pre class=\"EnlighterJSRAW\" data-enlighter-language=\"generic\" data-enlighter-group=\"hc_sr04.ino\" data-enlighter-title=\"hc_sr04.ino\">int triggerPin = 12;\r\nint echoPin = 11;\r\n\r\nvoid setup(){\r\n  pinMode(triggerPin, OUTPUT);\r\n  pinMode(echoPin, INPUT);\r\n  Serial.begin(9600);\r\n  delay(30);\r\n}\r\n\r\nvoid loop(){\r\n  digitalWrite(triggerPin, HIGH);\r\n  delayMicroseconds(20);\r\n  digitalWrite(triggerPin, LOW);\r\n  unsigned long duration = pulseIn(echoPin, HIGH);\r\n \r\n  int cmDistance = duration * 0.03432 \/ 2; \r\n  Serial.print(\"Distanz [cm]: \");\r\n  Serial.println(cmDistance);\r\n  \r\n  delay(3000);\r\n}<\/pre>\r\n<p>&nbsp;<\/p>\r\n\n<p>I have set a rising edge as the trigger. The trigger signal for the HC-SR04 module is also the trigger for the Logic Analyzer. This is what a measurement in Logic 2 looked like (about 20 cm distance):<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_1-1024x411.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"411\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_1-1024x411.png\" alt=\"\" class=\"wp-image-13609\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_1-1024x411.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_1-300x120.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_1-768x308.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_1-1320x530.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_1.png 1537w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>HC-SR04<\/figcaption><\/figure>\n<p>You can see how &#8211; after the short trigger signal and a certain latency &#8211; the echo pin goes to HIGH level and then back to zero when the echo is received. To determine the duration of latency, I set markers. This function can be found in the main menu under &#8220;Measure&#8221;. So the trigger signal is 22.25 microseconds and the latency is 443.75 microseconds.<\/p>\r\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_2.png\"><img loading=\"lazy\" decoding=\"async\" width=\"901\" height=\"347\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_2.png\" alt=\"\" class=\"wp-image-13611\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_2.png 901w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_2-300x116.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_2-768x296.png 768w\" sizes=\"auto, (max-width: 901px) 100vw, 901px\" \/><\/a><figcaption>Marker<\/figcaption><\/figure>\n<p>However, this can be displayed even more clearly. For this purpose, there are &#8220;Measurements&#8221;, which you can access via the ruler symbol in the side menu. Click the &#8220;+&#8221; icon, and then click &#8220;Add Measurement&#8221;. If you then point the mouse at the result curve, a vertical red line appears which you can move and which snaps into place at markers and signal edges. After a left click, you can define the measuring range. It may sound complicated, but it&#8217;s simple and intuitive.<\/p>\r\n<p>You can give the measuring ranges names and color them differently:<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_3-1024x338.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"338\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_3-1024x338.png\" alt=\"Measurements\" class=\"wp-image-13613\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_3-1024x338.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_3-300x99.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_3-768x253.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_3-1320x435.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Logic2_hc_sr04_3.png 1537w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Measurements<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\" id=\"analyzers\">Analyzers<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"alignright size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Analyzer.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Analyzer.png\" alt=\"\" class=\"wp-image-13643\" width=\"218\" height=\"145\"\/><\/a><\/figure><\/div>\n\n<p><a id=\"analyzers\"><\/a>Now we move on to a really useful function, the so-called analyzers. This allows you to analyze the I2C, SPI or serial communication of your microcontroller with other components.<\/p>\r\n<p>You activate the analyzer via the &#8220;1F&#8221; icon in the side menu. Then choose I2C, SPI or Async Serial. Depending on the selection, you have to make further settings.<a id=\"Async_Serial\"><\/a><\/p>\r\n\n<h3 class=\"wp-block-heading\" id=\"analyzer-beispiel-1-async-serial-softwareserial\">Analyzer Example 1: Async Serial \/ SoftwareSerial<\/h3>\n\n<p>First, let&#8217;s look at serial communication using the example of a SoftwareSerial connection. Download the following SoftwareSerial sketch to your board.<\/p>\r\n\n<pre class=\"EnlighterJSRAW\" data-enlighter-language=\"generic\" data-enlighter-group=\"SoftwareSerial.ino\" data-enlighter-title=\"SoftwareSerial.ino\">#include &lt;SoftwareSerial.h&gt;\r\nSoftwareSerial mySerial(10,11);\r\n\r\nvoid setup() {\r\n  Serial.begin(9600);\r\n  Serial.println(\"Let's start!\");\r\n  mySerial.begin(9600);\r\n}\r\n\r\nvoid loop() { \/\/ run over and over\r\n  if (mySerial.available()) {\r\n    Serial.write(mySerial.read());\r\n  }\r\n  if (Serial.available()) {\r\n    mySerial.write(Serial.read());\r\n  }\r\n}<\/pre>\r\n<p>&nbsp;<\/p>\r\n\n<p>You connect the TX pin (here: pin 11) to the Logic Analyzer. Of course, you must not forget the GND connection.<\/p>\r\n<p>Now select &#8220;Async Serial&#8221;, whereupon a window opens with the details of the serial connection. Set the input channel and the baud rate you set. Normally, the other settings do not need to be changed. We will come to the options &#8220;Show in protocol results table&#8221; and &#8220;Stream to terminal&#8221; later.<\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/serial_analyzer.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/serial_analyzer.png\" alt=\"Async Serial Analyzer Settings\" class=\"wp-image-13647\" width=\"255\" height=\"350\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/serial_analyzer.png 510w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/serial_analyzer-219x300.png 219w\" sizes=\"auto, (max-width: 255px) 100vw, 255px\" \/><\/a><figcaption>Async Serial Analyzer Settings<\/figcaption><\/figure><\/div>\n\n<p>For my example, the trigger method makes sense.<\/p>\r\n<p>Since TX is usually HIGH and the signals are LOW, you should choose falling edge as a trigger. By the way, I did that wrong below, but then left it that way to show what happens \u2192 the trigger is not at the beginning of the signal.<\/p>\r\n<p>Start the measurement and open the serial monitor. Send any message. I took the good old &#8220;Hello World!&#8221; The trigger should start data acquisition. After the time you set, the measurement stops.<\/p>\r\n<p>You will see that not only the signal, but also its meaning is displayed. By right-clicking on the bars above the signal, a selection menu appears in which you can choose between binary, decimal, hexadecimal and ASCII. Here&#8217;s what it looks like with ASCII:<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world-1024x226.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"226\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world-1024x226.png\" alt=\"Async Serial Analyzer\" class=\"wp-image-13649\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world-1024x226.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world-300x66.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world-768x169.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world-1320x291.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world.png 1537w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Async Serial Analyzer<\/figcaption><\/figure>\n<p>You can see that the transmission of &#8220;Hello World&#8221; takes about 12 milliseconds at a baud rate of 9600. As expected, the process is correspondingly faster with 115200 BAUD:<\/p>\r\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world_fast-1024x177.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world_fast-1024x177.png\" alt=\"\" class=\"wp-image-13651\" width=\"840\" height=\"145\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world_fast-1024x177.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world_fast-300x52.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world_fast-768x132.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world_fast-1320x228.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/Serial_hello_world_fast.png 1537w\" sizes=\"auto, (max-width: 840px) 100vw, 840px\" \/><\/a><figcaption>Async Serial Analyzer: Influence of baud rate. <\/figcaption><\/figure>\n<p>If you want to repeat this yourself, don&#8217;t forget to change the baud rate in Logic 2 as well. This is what you do in the Analyzers section \u2192 the three dots behind &#8220;Async Serial&#8221; \u2192 Edit. There you also switch the analyser off again. If you forget this and carry out other measurements, you will get &#8220;frame errors&#8221;, which are noticeable by exclamation marks above the signals.<a id=\"i2c\"><\/a><\/p>\r\n\n<h3 class=\"wp-block-heading\" id=\"analyzer-beispiel-2-i2c\">Analyzer Example 2: I2C<\/h3>\n\n<div class=\"wp-block-image\"><figure class=\"alignright size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose.png\" alt=\"\" class=\"wp-image-13653\" width=\"224\" height=\"125\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose.png 447w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose-300x167.png 300w\" sizes=\"auto, (max-width: 224px) 100vw, 224px\" \/><\/a><\/figure><\/div>\n\n<p>To try out the I2C Analyzer, take any I2C module and connect it to your microcontroller. Upload a suitable sketch that ensures communication between your microcontroller and the I2C component. I chose an INA219 current sensor and a sketch that regularly queries INA219 readings.<\/p>\r\n<p>In Logic 2 you choose the Analyzer I2C. You will then be asked for the channels for SDA and SCL.&nbsp; If not already done, connect the SDA \/ SCL lines to the selected channel pins.<\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose_channels.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose_channels.png\" alt=\"\" class=\"wp-image-13655\" width=\"386\" height=\"161\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose_channels.png 515w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_choose_channels-300x125.png 300w\" sizes=\"auto, (max-width: 386px) 100vw, 386px\" \/><\/a><figcaption>Selection of channels for I2C analysis<\/figcaption><\/figure><\/div>\n\n<p>For the control of the measurement, I would again choose the trigger mode so that I do not have to search for the signals in the recording. Since the I2C lines are HIGH in the ground state, the falling edge is again the trigger.<\/p>\r\n<p>In my example, the INA219 module has the I2C address 0x40. The registers are 0x01 and 0x02 are read. Query and response are easy to track:<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_analyze-1024x251.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"251\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_analyze-1024x251.png\" alt=\"I2C analysis with the Logic Analyzer\" class=\"wp-image-13660\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_analyze-1024x251.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_analyze-300x73.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_analyze-768x188.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_analyze-1320x323.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_analyze.png 1537w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>I2C analysis with the Logic Analyzer<\/figcaption><\/figure>\n<p>Here I have set the I2C frequency with <code>setWireClock(400000)<\/code> to 400 kHz:<\/p>\r\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Wire_400k.png\"><img loading=\"lazy\" decoding=\"async\" width=\"931\" height=\"335\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Wire_400k.png\" alt=\"2C analysis with the Logic Analyzer in Fast Mode (400 kHz)\" class=\"wp-image-13657\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Wire_400k.png 931w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Wire_400k-300x108.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Wire_400k-768x276.png 768w\" sizes=\"auto, (max-width: 931px) 100vw, 931px\" \/><\/a><figcaption>I2C analysis in Fast Mode (400 kHz)<\/figcaption><\/figure>\n<p>As expected, the clock speed quadruples. <a id=\"analyzer_export\"><\/a><\/p>\r\n\n<h2 class=\"wp-block-heading\" id=\"daten-des-logic-analyzer-exportieren\">Export Logic Analyzer data<\/h2>\n\n<p>First of all, you can view the data evaluated by the analyzer, provided that you have set the previously mentioned but not explained ticks at &#8220;Show in protocol results table&#8221; and &#8220;Stream to terminal&#8221;. Here is the data in the terminal:<\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C__Terminal.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C__Terminal.png\" alt=\"\" class=\"wp-image-13673\" width=\"275\" height=\"213\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C__Terminal.png 366w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C__Terminal-300x233.png 300w\" sizes=\"auto, (max-width: 275px) 100vw, 275px\" \/><\/a><figcaption>I2C measurement data in the terminal<\/figcaption><\/figure><\/div>\n\n<p>And here is the data in the data table:<\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Data_table.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Data_table.png\" alt=\"I2C measurement data of the Logic Analyzer in the data table\" class=\"wp-image-13664\" width=\"652\" height=\"411\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Data_table.png 869w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Data_table-300x189.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Data_table-768x484.png 768w\" sizes=\"auto, (max-width: 652px) 100vw, 652px\" \/><\/a><figcaption>I2C measurement data in the data table<\/figcaption><\/figure><\/div>\n\n<p>To export the data, click on the three dots to the right of &#8220;Type to search&#8221;. Click on the columns you want to export and then go to &#8220;Export Table&#8221;.<\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Table.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Table.png\" alt=\"Options for exporting data from Logic 2\" class=\"wp-image-13668\" width=\"518\" height=\"347\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Table.png 690w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Table-300x201.png 300w\" sizes=\"auto, (max-width: 518px) 100vw, 518px\" \/><\/a><figcaption>Options for exporting data from Logic 2<\/figcaption><\/figure><\/div>\n\n<p>Another window will open where you can choose more options:<\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/export_options.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/export_options.png\" alt=\"\" class=\"wp-image-13675\" width=\"306\" height=\"318\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/export_options.png 408w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/export_options-289x300.png 289w\" sizes=\"auto, (max-width: 306px) 100vw, 306px\" \/><\/a><figcaption>More Options<\/figcaption><\/figure><\/div>\n\n<p>Now click on &#8220;Export&#8221;. You choose a file name and a directory for your &#8220;.csv&#8221; file and save it. Then you can import the file into Excel, for example to evaluate it statistically or to create graphics:<a id=\"raw_export\"><\/a><\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_exported_table.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_exported_table.png\" alt=\"Import of the .csv file into Excel\" class=\"wp-image-13677\" width=\"429\" height=\"244\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_exported_table.png 572w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_exported_table-300x170.png 300w\" sizes=\"auto, (max-width: 429px) 100vw, 429px\" \/><\/a><figcaption>Import of the .csv file into Excel<\/figcaption><\/figure><\/div>\n\n<h2 class=\"wp-block-heading\" id=\"rohdaten-exportieren\">Export raw data<\/h2>\n\n<p><a id=\"raw_export\"><\/a>Alternatively, you can also export unevaluated raw data. These only contain the time and state of the selected channels. You can access the function via File \u2192 Export Data.<a id=\"other\"><\/a><\/p>\r\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Data.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Data.png\" alt=\"Raw Data Export with Logic Analyzer\" class=\"wp-image-13670\" width=\"318\" height=\"348\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Data.png 636w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/I2C_Export_Data-274x300.png 274w\" sizes=\"auto, (max-width: 318px) 100vw, 318px\" \/><\/a><figcaption>Raw data export<\/figcaption><\/figure><\/div>\n\n<h2 class=\"wp-block-heading\" id=\"weitere-anwendungen\">Other applications<\/h2>\n\n<h3 class=\"wp-block-heading\" id=\"433-mhz-signale-analysieren\">Analyze 433 MHz signals<\/h3>\n\n<p>In this example, I used the Logic Analyzer to capture a 433 MHz signal at the data output of a receiver. The signal was supplied by a remote control for a radio socket. The challenge is that the receiver without a &#8220;real&#8221; signal provides a lively data salad (see below, to the left of the trigger marker). Here it helped to select a LOW Pulse with a certain minimum width as a trigger.<\/p>\r\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz-1024x127.png\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz-1024x127.png\" alt=\"433 MHz signal\" class=\"wp-image-13682\" width=\"840\" height=\"104\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz-1024x127.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz-300x37.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz-768x96.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz-1536x191.png 1536w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz-1320x164.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/433_MHz.png 1920w\" sizes=\"auto, (max-width: 840px) 100vw, 840px\" \/><\/a><figcaption>433 MHz signal<\/figcaption><\/figure>\n<h3 class=\"wp-block-heading\" id=\"ir-signale-analysieren\">Analyze IR signals<\/h3>\n\n<p>And finally, here is an IR signal that I generated with the remote control of my SAT receiver and captured with an IR receiver diode:<\/p>\r\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/IR_Signal-1024x140.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"140\" src=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/IR_Signal-1024x140.png\" alt=\"IR Signal\" class=\"wp-image-13685\" srcset=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/IR_Signal-1024x140.png 1024w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/IR_Signal-300x41.png 300w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/IR_Signal-768x105.png 768w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/IR_Signal-1320x180.png 1320w, https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/IR_Signal.png 1537w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>IR Signal<\/figcaption><\/figure>\n<p>Here you can easily see the structure of the signal and could &#8220;recreate&#8221; the signal to simulate the remote control.<\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>The Logic Analyzer is a low-cost tool that allows you to analyze signals such as I2C, SPI, PWM and much more. I introduce the Analyzer and the Logic 2 software.<\/p>\n","protected":false},"author":1,"featured_media":13700,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[575],"tags":[1715,556,1710,1714,1712,666,1711,1708,1709,1713,1717,1718,1716,973,1219],"class_list":["post-13966","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-software-and-tools","tag-analyzer","tag-arduino-en-2","tag-async-serial-en","tag-export","tag-high-en","tag-i2c-en","tag-logic-2-en","tag-logic-analyzer-en","tag-looping-en","tag-low-en","tag-marker-en","tag-measurements-en","tag-softwareserial-en","tag-timer-en","tag-trigger-en-3"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Logic Analyzer &#8226; Wolles Elektronikkiste<\/title>\n<meta name=\"description\" content=\"The Logic Analyzer is a low-cost tool that allows you to analyze signals such as I2C, SPI, PWM and much more. This is an introduction.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Logic Analyzer &#8226; Wolles Elektronikkiste\" \/>\n<meta property=\"og:description\" content=\"The Logic Analyzer is a low-cost tool that allows you to analyze signals such as I2C, SPI, PWM and much more. This is an introduction.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer\" \/>\n<meta property=\"og:site_name\" content=\"Wolles Elektronikkiste\" \/>\n<meta property=\"article:published_time\" content=\"2022-03-11T19:54:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-04T14:12:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_post_image.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Wolfgang Ewald\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Wolfgang Ewald\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer\"},\"author\":{\"name\":\"Wolfgang Ewald\",\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en#\\\/schema\\\/person\\\/b774e4d64b4766889a2f7c6e5ec85b46\"},\"headline\":\"Logic Analyzer\",\"datePublished\":\"2022-03-11T19:54:08+00:00\",\"dateModified\":\"2022-11-04T14:12:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer\"},\"wordCount\":2432,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en#\\\/schema\\\/person\\\/b774e4d64b4766889a2f7c6e5ec85b46\"},\"image\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logic_analyzer_post_image.png\",\"keywords\":[\"analyzer\",\"Arduino\",\"async serial\",\"export\",\"HIGH\",\"I2C\",\"Logic 2\",\"Logic Analyzer\",\"looping\",\"LOW\",\"marker\",\"measurements\",\"SoftwareSerial\",\"timer\",\"trigger\"],\"articleSection\":[\"Software and tools\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer\",\"url\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer\",\"name\":\"Logic Analyzer &#8226; Wolles Elektronikkiste\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logic_analyzer_post_image.png\",\"datePublished\":\"2022-03-11T19:54:08+00:00\",\"dateModified\":\"2022-11-04T14:12:31+00:00\",\"description\":\"The Logic Analyzer is a low-cost tool that allows you to analyze signals such as I2C, SPI, PWM and much more. This is an introduction.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#primaryimage\",\"url\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logic_analyzer_post_image.png\",\"contentUrl\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logic_analyzer_post_image.png\",\"width\":1200,\"height\":1200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\\\/logic-analyzer#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Logic Analyzer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en#website\",\"url\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en\",\"name\":\"Wolles Elektronikkiste\",\"description\":\"Die wunderbare Welt der Elektronik\",\"publisher\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en#\\\/schema\\\/person\\\/b774e4d64b4766889a2f7c6e5ec85b46\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/en#\\\/schema\\\/person\\\/b774e4d64b4766889a2f7c6e5ec85b46\",\"name\":\"Wolfgang Ewald\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/cropped-Logo-1.png\",\"url\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/cropped-Logo-1.png\",\"contentUrl\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/cropped-Logo-1.png\",\"width\":512,\"height\":512,\"caption\":\"Wolfgang Ewald\"},\"logo\":{\"@id\":\"https:\\\/\\\/wolles-elektronikkiste.de\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/cropped-Logo-1.png\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Logic Analyzer &#8226; Wolles Elektronikkiste","description":"The Logic Analyzer is a low-cost tool that allows you to analyze signals such as I2C, SPI, PWM and much more. This is an introduction.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer","og_locale":"en_US","og_type":"article","og_title":"Logic Analyzer &#8226; Wolles Elektronikkiste","og_description":"The Logic Analyzer is a low-cost tool that allows you to analyze signals such as I2C, SPI, PWM and much more. This is an introduction.","og_url":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer","og_site_name":"Wolles Elektronikkiste","article_published_time":"2022-03-11T19:54:08+00:00","article_modified_time":"2022-11-04T14:12:31+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_post_image.png","type":"image\/png"}],"author":"Wolfgang Ewald","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Wolfgang Ewald","Est. reading time":"13 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#article","isPartOf":{"@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer"},"author":{"name":"Wolfgang Ewald","@id":"https:\/\/wolles-elektronikkiste.de\/en#\/schema\/person\/b774e4d64b4766889a2f7c6e5ec85b46"},"headline":"Logic Analyzer","datePublished":"2022-03-11T19:54:08+00:00","dateModified":"2022-11-04T14:12:31+00:00","mainEntityOfPage":{"@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer"},"wordCount":2432,"commentCount":0,"publisher":{"@id":"https:\/\/wolles-elektronikkiste.de\/en#\/schema\/person\/b774e4d64b4766889a2f7c6e5ec85b46"},"image":{"@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#primaryimage"},"thumbnailUrl":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_post_image.png","keywords":["analyzer","Arduino","async serial","export","HIGH","I2C","Logic 2","Logic Analyzer","looping","LOW","marker","measurements","SoftwareSerial","timer","trigger"],"articleSection":["Software and tools"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#respond"]}]},{"@type":"WebPage","@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer","url":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer","name":"Logic Analyzer &#8226; Wolles Elektronikkiste","isPartOf":{"@id":"https:\/\/wolles-elektronikkiste.de\/en#website"},"primaryImageOfPage":{"@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#primaryimage"},"image":{"@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#primaryimage"},"thumbnailUrl":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_post_image.png","datePublished":"2022-03-11T19:54:08+00:00","dateModified":"2022-11-04T14:12:31+00:00","description":"The Logic Analyzer is a low-cost tool that allows you to analyze signals such as I2C, SPI, PWM and much more. This is an introduction.","breadcrumb":{"@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#primaryimage","url":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_post_image.png","contentUrl":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2022\/01\/logic_analyzer_post_image.png","width":1200,"height":1200},{"@type":"BreadcrumbList","@id":"https:\/\/wolles-elektronikkiste.de\/en\/logic-analyzer#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/wolles-elektronikkiste.de\/en"},{"@type":"ListItem","position":2,"name":"Logic Analyzer"}]},{"@type":"WebSite","@id":"https:\/\/wolles-elektronikkiste.de\/en#website","url":"https:\/\/wolles-elektronikkiste.de\/en","name":"Wolles Elektronikkiste","description":"Die wunderbare Welt der Elektronik","publisher":{"@id":"https:\/\/wolles-elektronikkiste.de\/en#\/schema\/person\/b774e4d64b4766889a2f7c6e5ec85b46"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wolles-elektronikkiste.de\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/wolles-elektronikkiste.de\/en#\/schema\/person\/b774e4d64b4766889a2f7c6e5ec85b46","name":"Wolfgang Ewald","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2019\/03\/cropped-Logo-1.png","url":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2019\/03\/cropped-Logo-1.png","contentUrl":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2019\/03\/cropped-Logo-1.png","width":512,"height":512,"caption":"Wolfgang Ewald"},"logo":{"@id":"https:\/\/wolles-elektronikkiste.de\/wp-content\/uploads\/2019\/03\/cropped-Logo-1.png"}}]}},"_links":{"self":[{"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/posts\/13966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/comments?post=13966"}],"version-history":[{"count":0,"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/posts\/13966\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/media\/13700"}],"wp:attachment":[{"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/media?parent=13966"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/categories?post=13966"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wolles-elektronikkiste.de\/en\/wp-json\/wp\/v2\/tags?post=13966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}